Filnor Inc. Class 3010 Hoist Controller and Class 3011 Travel Controllers
- Recommended for use with AC Wound Rotor Motors
- Applications Include Heavy or Severe Duty Cranes, Magnet or Bucket Cranes
- Mill Duty Clapper Type Contactors used throughout Controllers
- Nema 12 Enclosure Standard
- Customer Specified Component Manufacturer
Examples of Our Products:
- CLASS 3010 HOIST CONTROL SYSTEMS
- Type “R” - Reversing for use with Mechanical Load Brake
- Type “DL” - Reversing Dynamic Lowering using Single Phase Motor Connection. Suitable for Applications NOT requiring Slow Lowering Speeds
- Type “ECB” - Reversing with Eddy Current Electric Load Brake. Provides Slow Hoisting and Lowering for ALL Loads
- Type “CT” - Reversing Counter Torque, Provides Slow Hoisting and Lowering Speeds for Overhauling Loads ONLY
- Recommended for Magnet or Bucket Cranes
- CMAA Classification D, E, & F Service
- NEMA Class I Service
- For Hoist, Trolley and Bridge Service
- CLASS 3011 TRAVEL CONTROL SYSTEMS
- Type “R” - Reversing Control
- Type “RP” - Reversing Plugging
- Type “DRP” - Duplex Reversing Plugging
- CMAA Classification D, E, & F Service
- NEMA Class I Service
- For Hoist, Trolley and Bridge Service
- Filnor Inc. Class 3200 AC Industrial Duty Crane Control
- For Hoist, Trolley and Bridge Service
- NEMA Class I. II Service
- CMAA Classification A, B, C, & D Service
- CLASS 3200 HOIST CONTROL SYSTEMS
- Type “R” - Reversing for use with Mechanical Load Brake
- Type “DL” - Reversing Dynamic Lowering using Single Phase Motor Connection.
- Suitable for Applications NOT requiring Slow Lowering Speeds
- Type “ECB” - Reversing with Eddy Current Electric Load Brake. Provides Slow Hoisting and Lowering for ALL Loads.
REQUIRED INFORMATION - CLASS 3010 AND 3011
MAIN HOIST MOTION
Quantity of Motors
Horsepower
Motor Primary Voltage – ( 575V, 480V or 230V )
Motor Primary Amps
Motor Secondary Amps
Nema Class of Resistors ( CL 162, CL 172, CL 92 )
Motor Secondary Voltage
Number of Speeds ( 1 thru 6 )
Type of Hoist Control ( R, DL, ECB, CT )
Are Drawings Available ( YES, NO )
Manufacturer of Hoist Control Scheme ( SQUARE’D, CUTLER-HAMMER, WESTINGHOUSE, GE, HUBBELL )
Type of Enclosure ( Nema 1 Gasketed, 12, 3R )
Nema Class Service ( D, E, F )
Main Disconnect
– Knife Switch ( Unfused or Fused )
– Circuit Breaker
Other Features Required ( Time Current Module, Frequency Relays, Phase Loss Relay, Etc.)
AUXILIARY HOIST MOTION
Quantity of Motors
Horsepower
Motor Primary Voltage – ( 575V, 480V or 230V )
Motor Primary Amps
Motor Secondary Amps
Nema Class of Resistors ( CL 162, CL 172, CL 92 )
Motor Secondary Voltage
Number of Speeds ( 1 thru 6 )
Type of Hoist Control ( R, DL, ECB, CT )
Are Drawings Available ( YES, NO )
Manufacturer of Hoist Control Scheme ( SQUARE’D, CUTLER-HAMMER, WESTINGHOUSE, GE, HUBBELL )
Type of Enclosure ( Nema 1 Gasketed, 12, 3R )
Nema Class Service ( D, E, F )
Main Disconnect
– Knife Switch ( Unfused or Fused )
– Circuit Breaker
Other Features Required ( Time Current Module, Frequency Relays, Phase Loss Relay, Etc. )
TROLLEY MOTION
Quantity of Motors
Horsepower
Motor Primary Voltage – ( 575V, 480V or 230V )
Motor Primary Amps
Motor Secondary Amps
Nema Class of Resistors ( CL 162, CL 172, CL 92 )
Motor Secondary Voltage
Number of Speeds ( 1 thru 6 )
Type of Trolley Control ( R, RP )
Are Drawings Available ( YES, NO )
Type of Enclosure ( Nema 1 Gasketed, 12, 3R )
Nema Class Service ( D, E, F )
Main Disconnect
– Knife Switch ( Unfused or Fused )
– Circuit Breaker
Other Features Required ( Time Current Module, Frequency Relays, Phase Loss Relay, Etc. )
BRIDGE MOTION
Quantity of Motors
Horsepower
Motor Primary Voltage – ( 575V, 480V or 230V )
Motor Primary Amps
Motor Secondary Amps
Nema Class of Resistors ( CL 162, CL 172, CL 92 )
Motor Secondary Voltage
Number of Speeds ( 1 thru 6)
Type of Bridge Control ( R, RP, DRP )
Are Drawings Available ( YES, NO )
Type of Enclosure ( Nema 1 Gasketed, 12, 3R )
Nema Class Service ( D, E, F )
Main Disconnect
– Knife Switch ( Unfused or Fused )
– Circuit Breaker
Other Features Required ( Time Current Module, Frequency Relays, Phase Loss Relay, Etc.)
MANUAL MAGNETIC DISCONNECT SWITCH
Total Horsepower
Motor Primary Voltage – ( 575V, 480V or 230V )
Type of Enclosure ( Nema 1 Gasketed, 12, 3R )
Main Disconnect
– Knife Switch ( Unfused or Fused )
– Circuit Breaker
REQUIRED INFORMATION - CLASS 3200
MAIN HOIST MOTION
Quantity of Motors
Horsepower
Motor Primary Voltage – ( 575V, 480V or 230V )
Motor Primary Amps
Motor Secondary Voltage
Motor Secondary Amps
Number of Speeds ( 1 thru 6 )
Nema Class of Resistors ( CL 162, CL 172, CL 92 )
Type of Hoist Control ( R, DL, ECB )
Are Drawing Available ( YES, NO )
Manufacturer of Hoist Control Scheme
( SQUARE’D, CUTLER-HAMMER, WESTINGHOUSE, GE, HUBBELL )
Type of Enclosure ( Nema 1 Gasketed, 12, 3R, 4, 4X )
Nema Class Service ( A, B, C, D )
Main Disconnect
– Knife Switch ( Unfused or Fused )
– Circuit Breaker
Other Features Required ( Time Current Module, Frequency Relays, Phase Loss Relay, Etc.)
AUXILIARY HOIST MOTION
Quantity of Motors
Horsepower
Motor Primary Voltage – ( 575V, 480V or 230V )
Motor Primary Amps
Motor Secondary Voltage
Motor Secondary Amps
Number of Speeds ( 1 thru 6 )
Nema Class of Resistors ( CL 162, CL 172, CL 92 )
Type of Hoist Control ( R, DL, ECB )
Are Drawings Available ( YES, NO)
Manufacturer of Hoist Control Scheme
( SQUARE’D, CUTLER-HAMMER, WESTINGHOUSE, GE, HUBBELL )
Type of Enclosure ( Nema 1 Gasketed, 12, 3R, 4, 4X )
Nema Class Service ( A, B, C, D )
Main Disconnect
– Knife Switch ( Unfused or Fused )
– Circuit Breaker
Other Features Required ( Time Current Module, Frequency Relays, Phase Loss Relay, Etc.)
TROLLEY MOTION
Quantity of Motors
Horsepower
Motor Primary Voltage – ( 575V, 480V or 230V )
Motor Primary Amps
Motor Secondary Voltage
Motor Secondary Amps
Number of Speeds ( 1 thru 6 )
Nema Class of Resistors ( CL 162, CL 172, CL 92 )
Type of Trolley Control ( R, RP )
Are Drawings Available ( YES, NO )
Type of Enclosure ( Nema 1 Gasketed, 12, 3R, 4, 4X )
Nema Class Service ( A, B, C, D )
Main Disconnect
– Knife Switch ( Unfused or Fused )
– Circuit Breaker
Other Features Required ( Time Current Module, Frequency Relays, Phase Loss Relay, Etc.)
BRIDGE MOTION
Quantity of Motors
Horsepower
Motor Primary Voltage – ( 575V, 480V or 230V )
Motor Primary Amps
Motor Secondary Voltage
Motor Secondary Amps
Number of Speeds ( 1 thru 6 )
Nema Class of Resistors ( CL 162, CL 172, CL 92 )
Type of Bridge Control ( R, RP )
Are Drawings Available ( YES, NO )
Type of Enclosure ( Nema 1 Gasketed, 12, 3R, 4, 4X )
Nema Class Service ( A, B, C, D )
Main Disconnect
– Knife Switch ( Unfused or Fused )
– Circuit Breaker
Other Features Required ( Time Current Module, Frequency Relays, Phase Loss Relay, Etc. )
MAIN LINE EQUIPMENT
Total Horsepower
Motor Primary Voltage – ( 575V, 480V or 230V )
Type of Enclosure ( Nema 1 Gasketed, 12, 3R, 4, 4X )
Main Disconnect
– Knife Switch ( Unfused or Fused )
– Circuit Breaker
– Thru-the-Door Operator ( Unfused or Fused )